Recent Plumbing Projects (Pins) Near Murrieta, CA

Most Recent Pins (1375)

Alyson Hastings
Plumber performed hydro jetting of main sewer line to remove root intrusion. Plumber was successful at removing root build up in line and verified with camera inspection. Plumber will send estimate for dig up to fully repair compromise section.
Pin Photo
Alyson Hastings
Toilet backed up R&R advised to auger toilet in attempt to remove blockage. Upon completion of work R&R flushed toilet numerous times to ensure proper functionality
Pin Photo
Alyson Hastings
Customer concerned it’s frozen tub spout. Tub spout is unable to divert shower head and tub setting. R&R recommends replacing tub spout in order to restore proper functionality.
Pin Photo
Alyson Hastings
Plumber removed gas valve that was leaking for customer. Customer had an electric dryer. Did not need gas plumber. Use a shorter nipple and a cab to cap off gas line for a customer plumber then tested gas line for leaks
Pin Photo
Alyson Hastings
Plumber flushed tankless water heater for 45 minutes using tankless solution after flushing for 45 minutes plumber ran water through the tankless system two times before disconnecting hoses to clean out the solution
Pin Photo
Alyson Hastings
Plumber drained and removed old water heater and dispose of unit at the dump. Plumber installed new water heater, adding in new water flex lines, new gas line with sediment trap attached to gas control and water heater catch pan. Plumber also added in new expansion tank to water heater cold inlet side of water heater. Plumber then filled heater and checked all connections made to ensure no leaks upon completion.
Pin Photo
Alyson Hastings
Plumber removed upstairs guest trap assembly to free blockage and clean trap assembly. Tested ok.
Pin Photo
Alyson Hastings
A plumber in Murrieta, California flushed a five-year-old 40-gallon Bradford White natural gas water heater. The process included draining the tank, flushing buildup, reconnecting supply lines, and restarting heating. The plumber also inspected all connections and checked the burner assembly for corrosion.
Pin Photo
Alyson Hastings
Upon arrival plumber found that shower cartridge and handle for shower in downstairs guest restroom was seized together and that the hand would need to be cut off in order to extract cartridge Plumber began buy shutting water off to home. Once off plumber then cut off shower handle and removed shower trim. Once removed plumber then extracted shower cartridge from valve. Once extracted plumber then installed a new Moen 1222 positemp shower cartridge. Once installed plumber then installed new shower trim and turned on water to home to test for leaks. Once no leaks were found plumber then caulked around the new shower trim and cleaned work area.
Pin Photo
Alyson Hastings
Remove and replace guest bathroom Kohler 1 piece toilet flush valve canister to eliminate running toilet. Tested toilet with no further faults or leaks from tank to bowl.
Pin Photo
Alyson Hastings
Alyson Hastings
A plumber in Temecula, California removed a reverse osmosis system under a kitchen sink, disconnected the waterline and isolation tee, replaced a damaged drain tailpiece, and installed a cover over the countertop hole left by the system’s spout.
Pin Photo
Alyson Hastings
Upon arrival customer existing garbage disposal was leaking internally and needed to be replaced R&R removed existing disposal only R&R provided and installed new12 hp garbage disposal Tested by filling sink up several times and releasing water through the drain No leaks
Pin Photo
Alyson Hastings
Plumber supplied and installed 34” gas seismic shut off valve to gas meter. Price reflects all parts and labor required to retrofit service.
Pin Photo
Alyson Hastings
Upon arrival plumber, found the angle stop and guest restroom for toilet was ruptured and allowing water to leak. Plumber began by shutting off water to home. Once watered to home was shut off plumber then. Removed ruptured angle from copper pipe. Once removed plumber then prepped new angle stop by applying threat sealant to threads of angle stop. Plumber then tighten compression style angle stop to half inch copper pipe. Once angle stop was installed plumber then turned on water and tested to ensure that there were no leaks and new angle stop was working properly. Plumber, then connected water supply line for toilet to new angle stop.
Pin Photo
Alyson Hastings
R&R augered urinal to clear clog Tested by flushing urinal several times Everything is draining properly at this time
Pin Photo
Alyson Hastings
Upon arrival customer needed tankless heater flushed R&R hooked up supply lines and pump and proceeded to pump descale solution through tankless heater for approximately 40 minutes R&R ran 25 gallons of clean water through tankless and restored gas and water
Pin Photo
Alyson Hastings
R and R Plumbing installed a 12 Grunfos recirculating pump with a timer and check valve beneath a 75-gallon water heater in a garage in Murrieta, California. This setup improves hot water availability and helps reduce wait times at fixtures.
Pin Photo
Alyson Hastings
Kitchen faucet replacement with new customer supplied kitchen faucet.
Pin Photo
Alyson Hastings
Leaking cold angle stop in downstairs guest bathroom sink vanity. Unable to close all the way. Gate valve in garage broken in the semi closed position choking off water volume to home. Remove and replace cold angle stop and 1.25” gate valve in garage. Installed new quarter turn angle stop with new supply line. Cut and soldered new ball valve with new union and 90 copper fitting. Replaced customer provided faucet cartridges in same bathroom at no additional charge. Turned water back on to home to test with no faults or leaks restoring valves to proper function.
Pin Photo
Alyson Hastings
Plumber performed sewer line repair in two separate locations of main sewer line leading to septic tank. Plumber had to cut out section of concrete and jackhammer to break up and remove to allow access to section with route intrusion found in camera inspection. Plumber excavated area next to home down to sewer line, removing clean out and root intrusion found to be at pipe connection to combination fitting. Plumber, then rebuilt section using a new pipe fittings and repair bands. Plumber, backfilled area, leaving new riser for two way clean out slightly above ground level. This cleanout allows, sneaking towards septic tank and up towards home. Plumber found during camera inspection, separate issue, located at septic tank tie in with offset and root intrusion. Plumber excavated down to septic tank lid and around sewer pipe, exposing 3 inch combination with faulty joint allowing roots into line. Plumber had to cut into sewer line and rebuild section adding a new ABS bands and combination fitting reconnecting sewer lines to septic line. Plumber notes that huge amounts of roots were found to be surrounding sewer line in multiple areas, and is caused by multiple pine trees being located on property. Plumber notes that due to roots surrounding sewer line that only six month warranty can be given on work due to not being able to control route intrusion in the future.
Pin Photo
Alyson Hastings
R and R Plumbing cleared a blockage in a bathtub and sink in Murrieta, California. The team cabled both drains to remove the obstruction, then tested water flow to confirm proper drainage and full functionality of both fixtures.
Pin Photo
Alyson Hastings
Mainline backed up Customer advised to cable mainline in attempt to remove blockage. Upon completion of of work R&R performed a camera inspection to determine cause of blockage and exposed severe paper build up on check valve location. No obstructions, offsets, or root intrusion were exposed
Pin Photo
Alyson Hastings
Upon arrival customers refrigerator was leaking internally and ice maker valve wouldn’t cease flow of water customer wanted line cut and capped and home is experiencing high pressure R&R cut out section of drywall to expose copper line cut and removed existing valve R&R provided fabricated and installed new 12 cap on ice maker line Restored water to the home and tested for leaks
Pin Photo
Alyson Hastings
Upon arrival customer needed new gas shut off valve installed R&R removed existing cap R&R provided and installed new 12 gas valve Tested for leaks
Pin Photo
Alyson Hastings
Upon arrival customer front yard hose bib piping was compromised and leaking R&R ceased flow of water to the home and cut out section of stucco to expose compromised piping that was leaking, cut and removed section of pipe R&R fabricated and installed new fittings and section of piping and installed existing threaded hose bib was Restored water to the home and tested for leaks
Pin Photo
Alyson Hastings
Upon arrival customer needed gas line extended to accommodate new kitchen stove R&R ceased flow of gas to the home and removed section of piping coming out of the wall and 90 R&R installed new section of pipe with new fittings and new gas valve Restored gas to the home and tested for leaks
Pin Photo
Alyson Hastings
Plumber installed a customer supplied envo skirted bidet toilet in the master bathroom. Plumber installed the same toilet in the master bathroom three years ago, but that one wasn’t working properly, so they sent the customer a new toilet. Plumber caulked the base , and told the homeowner not to use it for 24 hrs.
Pin Photo
Alyson Hastings
A plumber in Murrieta, California adjusted a gas line by removing a 34 x 12 inch T fitting, installing a half-inch T, lowering the line by 17 inches, and adding a new gas valve. The drywall behind the stove was opened for access, and the stove was reinstalled after the work was completed.
Pin Photo
Alyson Hastings
Plumber opened up drywall for customer to find the pinhole which was in the cold side half-inch copper type M. Plumber cut a section of pipe that had a pinhole in it and used a half inch for repair coupling to fix the leak. Plumber then turned on the water and made sure there was no other leaks.
Pin Photo
Alyson Hastings
Plumber replaced tank the bowl gasket with fluid master tank the ball gasket kit new hardware new gaskets. Plumber filled toilet tank up and check for leaks and flushed it a couple times making sure there is no other leaks
Pin Photo
Alyson Hastings
(1) Found the upstairs hallway bathroom two piece round front standard height toilet broken and needing replaced. The actual toilet tank is broken and not repairable. (2) Installed a new Western two piece round front standard height toilet as needed. This includes the new toilet, toilet seat, wax seal, water supply line and disposal of the old toilet.
Pin Photo
Alyson Hastings
WE WILL REPLACE ALL WATER PIPING WITHIN YOUR HOME WITH NEW PEX PIPING. THIS WILL INCLUDE ALL NEW ANGLE STOPS, SINK TOILETWATER HEATER FLEXIBLE SUPPLY LINES, WHOLE HOUSE WATER SHUT OFF VALVE (IF APPLICABLE), WATER PRESSURE REGULATOR (IF APPLICABLE), WASHING MACHINE AND ICEMAKER VALVES AND BOXES (IF APPLICABLE), AND NEW HOSE BIBS. DOES NOT INCLUDE ANY DRYWALL PATCHING, FAUCET REPLACEMENT, OR SHOWER VALVE REPLACEMENT.
Pin Photo
Alyson Hastings
Plumber installed a customer provided toilet in the upstairs guest bathroom. Used a new wax ring, nuts, bolts, supply line and clear caulking. Flushed many times to confirm there were no issues. Plumber hooked up kitchen sink to garbage disposal, new p trap with abs connections, dishwasher, garbage disposal button, and secured faucet. Ran water and drained dishwasher to confirm no leaks. Plumber had to access drywall under the laundry valves to cut out failed shut off valves that were soldered on. We supplied and soldered on new hot and cold shut off valves to restore proper function so another company can install washer and dryer. Used an access panel to cover hole. Installed oven and fridge and made sure both were in working order.
Pin Photo
Alyson Hastings
Plumber drained and removed existing working water heater. We supplied a new water heater stand and ran extended gas line, supply lines for the water, venting, and strapping the water heater to the opposite side of the garage door. This will make the water heater functional while remodel is ongoing in garage. After walls in cabinets are installed plumber will run new copper that will be behind water heater and close to the floor. Plumber will run copper with new shut off valves to feed washing machine. This pricing includes returning after remodels complete and reinstalling water heater and its original spot. Plumber ran a new inch and a half ABS drain line tied into the 2 inch existing drain line for a garage sink. We ran a new P-trap and connected to garage sink. Plumber rebuilt copper tied off of half-inch washing machine lines over to where new sink will be installed. We will also install two angle stops. After sink is installed we will connect supply lines to faucet and run water to make sure everything is working properly.
Pin Photo
Alyson Hastings
A plumber in Murrieta, California removed an old toilet, replaced the mounting hardware and wax ring, and installed a new customer-supplied toilet in a guest bathroom. The plumber connected the supply line, tested for leaks, applied caulk around the base, and cleaned the work area.
Pin Photo
Alyson Hastings
Upon arrival plumber found that the kitchen faucet had suddenly ruptured and would need to be replaced. Plumber began by shutting water to faucet at angle stops. Once off plumber then disconnected water supply lines and dismounted faucet from countertop. Once dismounted plumber then mounted a new Moen kitchen faucet. Once secured to counter top plumber then connected water supply lines to angle stops. Once installed plumber then turned on water at angle stops and tested to insure that the new faucet was working properly and that there where no leaks.
Pin Photo
Alyson Hastings
Plumber unable to locate trim parts for Kohler K304 shower valve. Only the cartridge and balancing assembly is available. Upon arrival plumber found the new shower valve would need to be installed. Plumber began by shutting off water to house. Once watered a home was shut off plumber then cut access in wall located behind downstairs guest restroom in the laundry room. Once access was cut plumber then Cut out old Kohler shower valve. Once cut out plumber then installed a new Moen Positemp temp shower valve and oil rubbed bronze shower trim. Once installed plumber, then turned on water to home and tested to ensure that there was no leaks and new valve was working properly. Once no leaks for found in new valve was working properly plumber then installed shower, trim, and caulked around shower trim plate to ensure that no leaks occur in wall.
Pin Photo
Alyson Hastings
Plumber came out to home to replace ice maker valve. Plumber needed to access drywall underneath ice maker valve box. Plumber removed existing ice maker valve. Plumber supplied and soldered in a new 14 turn ice maker valve in existing ice maker box. After installation, plumber restored water to home and confirmed there are no leaks at this time. Plumber installed a new customer supplied ice maker supply line and restored water to refrigerator and confirmed there are no leaks at this time.
Pin Photo
Alyson Hastings
Plumber came out to home for downstairs shower only getting hot water. Plumber removed existing shower trim and existing failed shower cartridge. Plumber supplied and installed a new Moen Posi-Temp shower cartridge in existing shower valve in wall. After installation, plumber restored water to home and confirmed there are no leaks and that shower gets both hot and cold water at this time. Plumber reinstalled existing shower trim and sealed to shower wall using new caulking.
Pin Photo
Alyson Hastings
Performed electronic leak detection finding the loudest point within the kitchen sink manifold. Cut dry wall to expose a single 12” cold line. Cut pipe and physically witnessed water draining in the pipe. Traced pipe to main cold manifold behind refrigerator consisting of a 1” main cold line, two 34” cold lines and a single 12” line. Cut 12” pipe to delete and leave burst line dead in slab. Reroute line from refrigerator manifold to kitchen sink manifold utilizing Type “A” Pex pipe and fittings. Secure all lines with isolation plugs and insulation. Turned water back on to home to test with no faults or leaks restoring water pressure system to proper function. Meter stable.
Pin Photo
Alyson Hastings
R and R Plumbing replaced a faulty fill valve and tank flapper in an upstairs master bathroom toilet in Murrieta, California. They also installed a new water supply line to stop the toilet from constantly running and ensure proper shutoff.
Pin Photo
Alyson Hastings
A plumber cleared a minor blockage in a kitchen sink drain in Temecula, California. The team restored full water flow and confirmed proper drainage by running water for an extended period after the repair.
Pin Photo
Alyson Hastings
A plumber in Murrieta, California removed an old guest bathroom toilet, replaced the wax ring and mounting hardware, and installed a new customer-provided toilet. They reconnected the water supply, tested the unit for leaks, applied caulk around the base, and cleaned the work area.
Pin Photo
Alyson Hastings
R and R Plumbing cleared a backed-up mainline in Hemet, California. Technicians used cabling to remove the blockage and then performed a camera inspection. The inspection found significant paper buildup near the check valve, identifying the source of the problem.
Pin Photo
Alyson Hastings
A plumber in Murrieta, California replaced failing laundry valves. They cut drywall to access the water pressure system, removed old valves, and installed new quarter-turn valves. The technician tested the system for leaks, secured the dryer hose, and checked all hoses. The system showed no faults or leaks after service.
Pin Photo
Alyson Hastings
R and R Plumbing removed tile, leveled mortar, and jackhammered concrete to access a drain line in Hemet, California. They rebuilt the ABS drain with a P-trap, set a new shower base, installed a Moen Posi-Temp valve, and secured wall panels with caulking and adhesive. All demo debris was removed. Drywall work was excluded.
Pin Photo
Alyson Hastings
A plumber installed a Noritz 98SV non-condensing tankless water heater in an attic in Murrieta, California. The service included new isolation valves, supply lines, a gas valve, gas line, and connection of the relief line to the AC condensation line. The system was tested and ran normally for ten minutes.
Pin Photo
Alyson Hastings
R and R Plumbing cleared a clogged kitchen sink drain in Temecula, California. The team removed the trap, snaked the drain line, and tested flow by repeatedly refilling and draining the sink. The system now drains correctly without backup.
Pin Photo
Alyson Hastings
R and R Plumbing replaced a faulty air gap and disposal hose in Temecula, California. The team removed the old components, installed new parts, and tested the system by running the dishwasher to ensure proper drainage and function.